CVE-2026-46746 PUBLISHED

Assigner: siemens
Reserved: 18.05.2026 Published: 09.06.2026 Updated: 09.06.2026

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins).

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS Score: 8.7

Product Status

Vendor Siemens
Product SINEC INS
Versions Default: unknown
  • affected from 0 to V1.0 SP2 Update 6 (excl.)

References

Problem Types

  • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') CWE