CVE-2025-30046 PUBLISHED

Remote Code Execution in CGM CLININET

Assigner: CERT-PL
Reserved: 14.03.2025 Published: 23.10.2026 Updated: 23.10.2026

In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. 

The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.

Metrics

CVSS Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
CVSS Score: 9

Product Status

Vendor CGM
Product CGM CLININET
Versions Default: unknown
  • affected from 0 to 2026.MS3 (incl.)

References

Problem Types

  • CWE-250 Execution with Unnecessary Privileges CWE