CVE-2026-107240 PUBLISHED

Assigner: hackerone
Reserved: 07.10.2026 Published: 10.11.2026 Updated: 10.11.2026

The Node.js web service on VOS (previously Versa FlexVNF) is used for URL-based Zero Touch Provisioning (ZTP) of the VOS appliance and is not required after provisioning is complete. The /authenticate endpoint of this service passes user-supplied username and password values to child_process.exec() through a sanitizer (escapeRegExp) that removes regular expression metacharacters but not newline characters. An unauthenticated attacker can inject a newline character into the username field to execute arbitrary shell commands as the versa OS service user. No credentials are required; the attacker needs only a CSRF token, which can be obtained from an unauthenticated page load. 

Versa’s security hardening guide for Hubs, Branches, and Controllers recommends disabling the Node.js web service after the initial provisioning of the VOS device. This vulnerability is not exploitable on VOS devices where the Node.js web service has been disabled.

Metrics

CVSS Vector: CVSS:3.0/AV:N/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H
CVSS Score: 7.6

Product Status

Vendor Versa
Product VOS
Versions
  • affected from 21.1.1 to 21.2.3 (incl.)
  • affected from 22.1.2 to July 2, 2026 (excl.)
  • affected from 22.1.3 to July 2, 2026 (excl.)
  • affected from 22.1.4 to July 2, 2026 (excl.)
  • affected from 23.1.2 to Aug 3, 2026 (excl.)
  • unaffected from 22.1.2 July-2-2026-Hotfix to 22.1.2 July-2-2026-Hotfix (excl.)
  • unaffected from 22.1.3 July-2-2026-Hotfix to 22.1.3 July-2-2026-Hotfix (excl.)
  • unaffected from 22.1.4 July-2-2026-Hotfix to 22.1.4 July-2-2026-Hotfix (excl.)
  • unaffected from 23.1.2 Aug-3-2026-Hotfix to 23.1.2 Aug-3-2026-Hotfix (excl.)

Workarounds

The mitigation is to disable the Nodejs web service on the VOS. Instructions to disable the Nodejs web service are available on the Versa documentation page at the below link:

https://docs.versa-networks.com/Integrations_and_Solutions/System_Hardening/Perform_Manual_Hardening_for_Versa_Branches%2C_Controllers%2C_and_Hubs#Enable_Secure_Mode

Credits

  • NCSC, Netherlands finder

References

Problem Types

  • CWE-78 OS Command Injection CWE