CVE-2026-16675 PUBLISHED

Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation

Assigner: Rockwell
Reserved: 22.07.2026 Published: 01.09.2026 Updated: 01.09.2026

A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.

Metrics

CVSS Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS Score: 8.5

Product Status

Vendor Rockwell Automation
Product FactoryTalk® Activation Manager
Versions Default: unaffected
  • Version Version 5.02 and below is affected

Solutions

Upgrade to version 5.03 or later.

References

Problem Types

  • CWE-307 Improper restriction of excessive authentication attempts CWE