CVE-2026-2192 PUBLISHED

Tenda AC9 formGetRebootTimer stack-based overflow

Assigner: VulDB
Reserved: 07.02.2026 Published: 08.02.2026 Updated: 08.02.2026

A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
CVSS Score: 8.6

Product Status

Vendor Tenda
Product AC9
Versions
  • Version 15.03.06.42_multi is affected

Credits

  • jfkk (VulDB User) reporter

References

Problem Types

  • Stack-based Buffer Overflow CWE
  • Memory Corruption CWE