CVE-2026-2330 PUBLISHED

CVE-2026-2330

Assigner: SICK AG
Reserved: 11.02.2026 Published: 06.03.2026 Updated: 06.03.2026

An attacker may access restricted filesystem areas on the device via the CROWN REST interface due to incomplete whitelist enforcement. Certain directories intended for internal testing were not covered by the whitelist and are accessible without authentication. An unauthenticated attacker could place a manipulated parameter file that becomes active after a reboot, allowing modification of critical device settings, including network configuration and application parameters.

Metrics

CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
CVSS Score: 9.4

Product Status

Vendor SICK AG
Product SICK Lector85x
Versions Default: affected
  • affected from 0 to 2.8.0 (excl.)
Vendor SICK AG
Product SICK Lector83x
Versions Default: affected
  • affected from 0 to 2.8.0 (excl.)

Solutions

Users are strongly recommended to upgrade to release version 2.8.0.

References

Problem Types

  • CWE-552 Files or Directories Accessible to External Parties CWE