CVE-2026-25857 PUBLISHED

Tenda G300-F Command Injection via formSetWanDiag

Assigner: VulnCheck
Reserved: 06.02.2026 Published: 07.02.2026 Updated: 07.02.2026

Tenda G300-F router firmware versio 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS Score: 8.6

Product Status

Vendor Shenzhen Tenda Technology
Product Tenda G300-F
Versions Default: unaffected
  • affected from 0 to 16.01.14.2 (incl.)

Credits

  • evan finder

References

Problem Types

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') CWE