CVE-2026-29127 PUBLISHED

Incorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100

Assigner: Gridware
Reserved: 04.03.2026 Published: 05.03.2026 Updated: 05.03.2026

The IDC SFX2100 Satellite Receiver sets overly permissive file system permissions on the monitor user's home directory. The directory is configured with permissions 0777, granting read, write, and execute access to all local users on the system, which may cause local privilege escalation depending on conditions of the system due to the presence of highly privileged processes and binaries residing within the affected directory.

Metrics

CVSS Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N
CVSS Score: 9.2

Product Status

Vendor International Datacasting Corporation
Product SFX2100 Satellite Receiver
Versions Default: affected
  • Version SFX2100 is affected

Credits

  • Abdul Mhanni finder

References

Problem Types

  • CWE-269 Improper Privilege Management CWE

Impacts

  • CAPEC-233 Privilege Escalation