CVE-2026-32840 PUBLISHED

Edimax GS-5008PL <= 1.00.54 Stored XSS via Device Name

Assigner: VulnCheck
Reserved: 16.03.2026 Published: 17.03.2026 Updated: 17.03.2026

Edimax GS-5008PL firmware version 1.00.54 and prior contain a stored cross-site scripting vulnerability in the system_name_set.cgi script that allows attackers to inject arbitrary script code by manipulating the sysName parameter. Attackers can send a crafted POST request with malicious script payload that executes when management pages including system_data.js are viewed by administrators.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N
CVSS Score: 5.1

Product Status

Vendor EDIMAX Technology Co., Ltd.
Product Edimax GS-5008PL
Versions Default: unknown
  • affected from 0 to 1.00.54 (incl.)

Credits

  • Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc. finder

References

Problem Types

  • CWE-79 Improper neutralization of input during web page generation ('cross-site scripting') CWE