CVE-2026-33272 PUBLISHED

Red Lion Controls N-Tron 700 Series Authentication Bypass Using an Alternate Path or Channel

Assigner: icscert
Reserved: 08.04.2026 Published: 09.10.2026 Updated: 09.10.2026

A malicious user with physical access to the device can boot the switch from factory settings without authentication, use the default administrative credentials to obtain administrative access, and save changes to the configuration file so that they persist next time the switch boots normally.

Metrics

CVSS Vector: CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:L/SI:H/SA:N
CVSS Score: 6.8

Product Status

Vendor Red Lion Controls
Product 700 Series
Versions Default: unaffected
  • affected from 0 to Firmware Versions 3.11.0 (excl.)
  • affected from 0 to Bootloader Versions 2.0.6.1 (excl.)
  • Version 3.11.1 is unaffected

Solutions

Red Lion controls recommends the following upgrades for the N-Tron 700 Series:

  • Upgrade to firmware version 3.11.1 or greater
  • Configure or disable the SNMP communities
  • Disable access to the web GUI

The upgrade procedure document can be viewed here https://www.hms-networks.com/ .

The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .

Credits

  • Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA. finder

References

Problem Types

  • CWE-288 CWE