CVE-2026-33892 PUBLISHED

Assigner: siemens
Reserved: 24.03.2026 Published: 14.04.2026 Updated: 14.04.2026

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.

Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L
CVSS Score: 5.1

Product Status

Vendor Siemens
Product Industrial Edge Management Pro V1
Versions Default: unknown
  • affected from V1.7.6 to V1.15.17 (excl.)
Vendor Siemens
Product Industrial Edge Management Pro V2
Versions Default: unknown
  • affected from V2.0.0 to V2.1.1 (excl.)
Vendor Siemens
Product Industrial Edge Management Virtual
Versions Default: unknown
  • affected from V2.2.0 to V2.8.0 (excl.)

References

Problem Types

  • CWE-305: Authentication Bypass by Primary Weakness CWE