CVE-2026-39460 PUBLISHED

Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials

Assigner: icscert
Reserved: 08.04.2026 Published: 09.10.2026 Updated: 09.10.2026

Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N
CVSS Score: 9.3

Product Status

Vendor Red Lion Controls
Product 700 Series
Versions Default: unaffected
  • affected from 0 to Firmware Versions 3.11.0 (excl.)
  • affected from 0 to Bootloader Versions 2.0.6.1 (excl.)
  • Version 3.11.1 is unaffected

Solutions

Red Lion controls recommends the following upgrades for the N-Tron 700 Series:

  • Upgrade to firmware version 3.11.1 or greater
  • Configure or disable the SNMP communities
  • Disable access to the web GUI

The upgrade procedure document can be viewed here https://www.hms-networks.com/ .

The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .

Credits

  • Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA. finder

References

Problem Types

  • CWE-522 CWE