CVE-2026-72895 PUBLISHED

Assigner: siemens
Reserved: 10.08.2026 Published: 13.10.2026 Updated: 13.10.2026

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Metrics

CVSS Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS Score: 8.4

Product Status

Vendor Siemens
Product SIMATIC IPC BX-21A
Versions Default: unknown
  • affected from 0 to V31.01.13 (excl.)
Vendor Siemens
Product SIMATIC IPC RW-543A
Versions Default: unknown
  • affected from 0 to V1.1.4 (excl.)
Vendor Siemens
Product SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G
Versions Default: unknown
  • affected from 0 to V28.01.15 (excl.)

References

Problem Types

  • CWE-1394: Use of Default Cryptographic Key CWE