CVE-2026-7849 PUBLISHED

Command Injection in SCM (idledisconnect parameter)

Assigner: CERTVDE
Reserved: 05.05.2026 Published: 30.07.2026 Updated: 30.07.2026

Due to improper neutralization of special elements, an unauthenticated remote attacker is able to inject a command into the system configuration which is subsequently executed as root.

Metrics

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS Score: 9.3

Product Status

Vendor Phoenix Contact
Product CHARX SEC-3150
Versions Default: unaffected
  • affected from 1.0.0 to 1.9.1 (excl.)
Vendor Phoenix Contact
Product CHARX SEC-3100
Versions Default: unaffected
  • affected from 1.0.0 to 1.9.1 (excl.)
Vendor Phoenix Contact
Product CHARX SEC-3050
Versions Default: unaffected
  • affected from 1.0.0 to 1.9.1 (excl.)
Vendor Phoenix Contact
Product CHARX SEC-3000
Versions Default: unaffected
  • affected from 1.0.0 to 1.9.1 (excl.)

Credits

  • ZDI finder

References

Problem Types

  • CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE