CVE-2026-78630 PUBLISHED

Improper Input Neutralization in Okta Access Gateway SNMP Configuration Processing

Assigner: Okta
Reserved: 24.08.2026 Published: 08.09.2026 Updated: 08.09.2026

The Okta Access Gateway does not neutralize shell metacharacters in SNMP configuration values before a privileged script uses them to construct OS commands. An authenticated local user with access to the management interface can supply crafted values, resulting in the execution of arbitrary OS commands with root privileges.

Metrics

CVSS Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS Score: 6.7

Product Status

Vendor Okta
Product Okta Access Gateway
Versions Default: unaffected
  • affected from 0 to 2026.9.1 (excl.)

Solutions

Upgrade the Okta Access Gateway appliance to version 2026.9.1 or greater.

References

Problem Types

  • Improper Neutralization of Special Elements used in an OS Command